Product Information

ManufacturerPolymaker
Product NamePolyMax PC
Filament TypePC
FinishEngineered

Print Conditions

Nozzle Temperature250-270 °C
Bed Temperature90-105 °C
Print Speed50-200 mm/s
Cooling FanOff
Retraction Distance1-3 mm
Retraction Speed20-40 mm/s
Build Surface MaterialsGlass, PEI

Technical Properties

Diameter1.75-2.85 mm ±0.03
Density1.19 g/cm³
Glass Transition Temperature113 °CDSC, 10°C/min
Vicat Softening Temperature117 °CISO 306
Heat Deflection Temperature @ 1.8MPa99 °CISO 75
Heat Deflection Temperature @ 0.45MPa114 °CISO 75
Melt Index6-8 g/10 min260°C, 1.2kg
Decomposition Temperature360 °C
Young's Modulus (X-Y)2435 MPa ±63ISO 527
Young's Modulus (Z)2149 MPa ±119ISO 527
Tensile Strength (X-Y)53.44 MPa ±0.6ISO 527
Tensile Strength (Z)41.43 MPa ±1.5ISO 527
Elongation at Break (X-Y)4.53 % ±0.45ISO 527
Elongation at Break (Z)2.79 % ±0.21ISO 527
Flexural Modulus (X-Y)2050 MPa ±79ISO 178
Flexural Strength (X-Y)81.29 MPa ±1.53ISO 178
Charpy Impact Strength (X-Y)21.28 kJ/m² ±1.69ISO 179
Low Temperature Impact (-30°C)9.2 kJ/m² ±1.5ISO 179

Additional Characteristics

Effect of Weak AcidsGoodhttps://wiki.polymaker.com/polymaker-products/more-about-our-products/documents/technical-data-sheets/polycarbonate/polymax-tm-pc
Effect of Weak AlkalisFairhttps://wiki.polymaker.com/polymaker-products/more-about-our-products/documents/technical-data-sheets/polycarbonate/polymax-tm-pc
Effect of Oils & GreaseGoodhttps://wiki.polymaker.com/polymaker-products/more-about-our-products/documents/technical-data-sheets/polycarbonate/polymax-tm-pc
Effect of Strong AcidsPoorhttps://wiki.polymaker.com/polymaker-products/more-about-our-products/documents/technical-data-sheets/polycarbonate/polymax-tm-pc
Effect of Strong AlkalisPoorhttps://wiki.polymaker.com/polymaker-products/more-about-our-products/documents/technical-data-sheets/polycarbonate/polymax-tm-pc

This data sheet is for quick reference only. Data is sourced from manufacturer specifications and should be verified. Always confirm specifications on the manufacturer's official website before making purchasing or design decisions. Report any issues or discrepancies using the button on the right.