Product Information

ManufacturerPolymaker
Product NameFiberon PET-GF15
Filament TypePET
FinishGlass Fiber

Print Conditions

Nozzle Temperature280-310 °C
Bed Temperature70-80 °C
Print Speed250 mm/s
Cooling FanOFF

Technical Properties

Density1.43 g/cm³ISO 1183, GB/T 1033
Melt index36.9 g/10 min270 °C, 2.16kg
Glass transition temperature59.5 °CDSC, 10 °C/min
Melting temperature231.6 °CDSC, 10 °C/min
Crystallization temperature201.4 °CDSC, 10 °C/min
Decomposition temperature422.8 °CTGA, 20 °C/min
Vicat softening temperature232.6 °CISO 306, GB/T 1633
Heat deflection temperature (1.8 MPa) (annealed)87.3 °CISO 75
Heat deflection temperature (0.45 MPa) (annealed)133.7 °CISO 75
Heat deflection temperature (1.8 MPa)71.8 °CISO 75
Heat deflection temperature (0.45 MPa)81.6 °CISO 75
Young's modulus (X-Y)4144.2 MPa ±133.3ISO 527, GB/T 1040
Young's modulus (Z)3428.9 MPa ±257.2ISO 527, GB/T 1040
Tensile strength (X-Y)59.9 MPa ±0.8ISO 527, GB/T 1040
Tensile strength (Z)48.2 MPa ±0.3ISO 527, GB/T 1040
Elongation at break (X-Y)4 % ±0.5ISO 527, GB/T 1040
Elongation at break (Z)2.6 % ±0.1ISO 527, GB/T 1040
Bending modulus (X-Y)3705.4 MPa ±84.5ISO 178, GB/T 9341
Bending modulus (Z)2998.4 MPa ±92.3ISO 178, GB/T 9341
Bending strength (X-Y)104.2 MPa ±2.4ISO 306, GB/T 1633
Bending strength (Z)80.3 MPa ±2.5ISO 306, GB/T 1633
Notched Charpy impact strength (X-Y)8.7 kJ/m² ±0.6ISO 179, GB/T 1043
Un-notched Charpy impact strength (X-Y)27.2 kJ/m² ±2ISO 179, GB/T 1043
Un-notched Charpy impact strength (Z)13.9 kJ/m² ±1.6ISO 179, GB/T 1043

Additional Characteristics

Flame retardancyHBData Sheet